THE PRESENT FIRMWARE WHICH IS FOR GUIDANCE ONLY AIMS AT PROVIDING CUSTOMERS WITH CODING INFORMATION REGARDING THEIR PRODUCTS IN ORDER FOR THEM TO SAVE TIME. AS A RESULT, WIZnet SHALL NOT BE HELD LIABLE FOR ANY DIRECT, INDIRECT OR CONSEQUENTIAL DAMAGES WITH RESPECT TO ANY CLAIMS ARISING FROM THE CONTENT OF SUCH FIRMWARE AND/OR THE USE MADE BY CUSTOMERS OF THE CODING INFORMATION CONTAINED HEREIN IN CONNECTION WITH THEIR PRODUCTS.
Example Description
This example shows how to use the PWM peripheral to run Dead-zone generation.
The PWM channel 0 frequency is set to SystemCoreClock(Hz), the Prescaler is 2 so the PWM channel 0 counter clock is 10 MHz. SystemCoreClock is set to 20 MHz.
The PWM channel 0 is set as up-count and periodic mode, and the dead-zone counter value is set as 100. The PWM output is enabled. So as a result, the output of PWM channel 1 is inverted the PWM channel 0 output.
- note:
- If you want to use the PWM channel 0 as dead-zone generation, the PWM channel 1 output MUST be disabled.
The PWM channel 0 output is mapped to PC_00, and inverted output is mapped to PC_01(The PWM channel 1 output).
Directory contents
- PWM/DeadZoneGeneration/main.c (Main program)
- PWM/DeadZoneGeneration/W7500x_it.c (Interrupt Handlers)
- PWM/DeadZoneGeneration/W7500x_it.h (Interrupt Handlers Header file)
- PWM/DeadZoneGeneration/W7500x_conf.h (Library Configuration file)
- PWM/DeadZoneGeneration/MDK/W7500x_PWM_DeadZoneGeneration.uvproj (MDK Project file)
- PWM/DeadZoneGeneration/GCC/Makefile (GCC Make file)
Hardware and Software environment
-
This example has been tested with WIZnet WIZwiki W7500 platform.
-
To select the WIZnet WIZwiki platform used to run the example.
-
WIZwiki W7500 Set-up
- PA_00 pin generates the PWM channel 0 output signal.
- PA_01 pin generates the inverted PWM channel 0 output signal.
- In order to use the PWM channel 0(PA_00) to be changed from PAD_AF0 to PAD_AF2.
- In order to use the inverted PWM channel 0(PA_01) to be changed from PAD_AF0 to PAD_AF2.
How to use it ?
In order to make the program work, you must do the following :
- Open your preferred toolchain.
- Rebuild all files and load your image into target memory.
- Run the example.
- WIZwiki W7500 where the Flash memory density ranges 128Kbytes.