Skip to main content

Getting Started

Unpacking the WIZ510SR-RP

What's in the Box?

The WIZ510SR-RP evaluation board package contains the following parts.

  • WIZ510SR-RP Module

The entire list of parts of the board is available at the WIZ510SR-RP Overview: Product Contents page.

As WIZ510SR-RP already has Serial and Ethernet port, no separate evaluation board is needed to get started working with module.

Device Layout

Figure: WIZ510SR-RP Revision 1.0 Top

Parts

ItemDescription
U1RP2040 MCU
U2W5100S
U4RS232 IC
U6Flash memory
J1Debug
J3Boot Mode
J4FACT RST
J5DP/DM Header
SW1Reset
SW2BOOTSEL
SW3HW TRIG
LD1~4LED indicators

Prerequisites for Setup

Software

  • Configuration tool program (Download page)
  • TCP server / TCP client / UDP terminal program
  • Serial terminal program

Hardware

  • Your WIZ510SR-RP module
  • Ethernet cable
  • DB9 serial RS-232 cable (for Data UART, RS-232/TTL Ver. only)
  • Power source for device
    • Such as 5V DC adapter, USB port on your computer, or 3.3V Power source
tip

J1, J3, J4 pins are not mounted.


Connect Your WIZ510SR-RP

WIZ510SR-RP Factory Settings

Network SettingsLocalIP address192.168.11.2-
::::::Gateway address192.168.11.1-
::::::Subnet mask255.255.255.0-
::::::DNS server8.8.8.8Google Public DNS
::::::Port number5000-
:::RemoteIP address192.168.11.3-
::::::Port number5000-
Serial Port SettingsData UART115200-8-N-1 / Flow Control: None-
:::Debug UART115200-8-N-1 / Flow Control: NoneFixed
  • Operation mode: TCP server mode
  • Debug message: Enabled
  • Serial command mode switch: Enabled
  • Serial command mode switch code: +++ (hex code, [2B][2B][2B])
  • Data packing option - Time: Disabled
  • Data packing option - Size: Disabled
  • Data packing option - Char: Disabled
  • Inactivity Timer: Disabled
  • Reconnection Timer: 3 second
  • Keep-Alive: Enabled, 7-sec initial delay, 5-sec send interval

PC Settings

Double check that the WIZ510SR-RP and the PC, or laptop you are using to set up WIZ510SR-RP with are both in the same Ethernet network.

Example: PC Network Settings

When the WIZ510SR-RP's settings are factory default,

Network SettingsPC or laptop
(= Remote)
IP address192.168.11.3-
::::::Gateway address192.168.11.1-
::::::Subnet mask255.255.255.0-
::::::Port number5000-
  • User should to matching the network settings of 'WIZ510SR-RP's remote host' and 'PC (or laptop)' for testing TCP client/mixed mode.
  • If the DHCP(automatic IP allocation) is used, both the WIZ510SR-RP and test PC must be set to be assigned the same IP from the same router.

Connecting Steps

The WIZ510SR-RP is designed to use the DB9 connector to connect with the user’s serial device. Therefore, it is recommended to have all Ethernet and serial ports connected to the PC when testing. If the PC does not have a serial port, please purchase a RS-232 to USB converter separately.

Step 1: Plug in

Connect cables to WIZ510SR-RP module as shown in the picture below.

  • Ethernet Cable
    • Used to connect the evaluation board’s RJ-45 connector and the PC’s Ethernet network interface card (PC's RJ-45 connector)
  • Serial Cable
    • Used to connect the evaluation board’s DB9 connector and the serial interface card (DB9 connector). If the PC does support serial interface, use the RS-232 to USB converter.

Image to be added

Step 2: Power on

Connect the 5V power adaptor or USB cable to the evaluation board and turn on the power switch.

  • The power LED will turn red once the evaluation board is on.

Image to be added

Open the configuration tool and click the search button. If the board is turned on and connected to the same network, the MAC address or settings of the WIZ510SR-RP module can be checked using the configuration tool.

Figure: WIZnet Configuration Tool

Step 4: Set up your WIZ510SR-RP

Change the settings accordingly to the customer’s environment. The test shown in this document is based on factory setting.

tip

Click Apply Settings button to save the changes in settings of the configuration tool.

Step 5: Connect

Connect the PC as the TCP client of the user’s serial device for data communication testing. In order to do this, the serial terminal program / TCP client terminal program must be opened on the PC. The serial terminal program and TCP client program must be set as below.

  • Serial terminal program: 115200-8-N-1, Flow control: None
  • TCP client program: 192.168.11.2:5000 (The IP address and port number of WIZ510SR-RP)

The COM port for serial terminal program connection can be checked as below.

  • Control Panel -> System -> Device Manager
Figure: Device Manager

Step 6: Verify

The basic data communication of the WIZ510SR-RP can be verified as below.

  • Serial to Ethernet: data communication verification
    • Enter the character string in the serial terminal and check if the identical character string appears on the TCP client terminal.
  • Ethernet to Serial: data communication verification
    • Enter the character string in the TCP client terminal and check if the identical character string appears on the serial terminal.

Step 7: Done

Now you’re ready to use the WIZ510SR-RP!

  • This document is based on the assumption of the PC as the serial device / remote network device.
  • The next step is to connect the WIZ510SR-RP module to the target serial device and check if the device can communicate, control, and monitor via the remote PC or monitoring server.

If there is any problem?

Please refer to our Troubleshooting guide!